ABB Air Circuit Breakers SACE Emax E4 S-HABB Air Circuit Breakers SACE Emax E4 S-H ABB Air Circuit Breakers SACE Emax E4 S-H-circuit breakers,potentiometers,contactor
Home > Products > Air Circuit Breaker > ABB Air Circuit Breakers > ABB Air Circuit Breakers SACE Emax E4 S-H

ABB Air Circuit Breakers SACE Emax E4 S-H

share

SPECIFICATIONS
Rated uninterrupted current(a 40°C)Iu: 3200,4000
Mechanical life with regular routine maintenance: 15
Frequency: 60
Electrical life: (440 V-)7,5
(690 V-)7,4

ABB Air Circuit Breakers SACE Emax E4S/f

ABB Air Circuit Breakers SACE Emax E4S/f


SPECIFICATIONSRated uninterrupted current(a 40°C)Iu: 4000Rated service voltage Ue: 690Rated short-time making capacity(peak value)Icm: 176Rated short-time withstand current Icw(1s): 80
ABB Air Circuit Breakers SACE Emax E2.2B 1600 Ekip Dip LI

ABB Air Circuit Breakers SACE Emax E2.2B 1600 Ekip Dip LI


SPECIFICATIONSRated uninterrupted current Iu: 1600Rated ultimate short-circuit breaking capacity Icu: 42Rated short-time withstand current Icw(1s): 42
ABB Air Circuit Breakers SACE Emax E2N/E

ABB Air Circuit Breakers SACE Emax E2N/E


SPECIFICATIONSRated uninterrupted current(a 40°C)Iu: 1250,1600,2000Rated service voltage Ue: 1000Rated ultimate short-circuit breaking capacity Icu: 30Rated short-time withstand current Icw(1s): 30
ABB Air Circuit Breakers SACE Emax E1.2N 250 Ekip Dip LI

ABB Air Circuit Breakers SACE Emax E1.2N 250 Ekip Dip LI


SPECIFICATIONSRated uninterrupted current Iu: 250Rated ultimate short-circuit breaking capacity Icu: 66Rated short-time withstand current Icw(1s): 50
ABB Air Circuit Breakers SACE Emax E2.2S 2500 Ekip Dip LI

ABB Air Circuit Breakers SACE Emax E2.2S 2500 Ekip Dip LI


SPECIFICATIONSRated uninterrupted current Iu: 2500Rated ultimate short-circuit breaking capacity Icu: 85Rated short-time withstand current Icw(1s): 66
ABB Air Circuit Breakers SACE Emax E2.2S 1000 Ekip Dip LI

ABB Air Circuit Breakers SACE Emax E2.2S 1000 Ekip Dip LI


SPECIFICATIONSRated uninterrupted current Iu: 1000Rated ultimate short-circuit breaking capacity Icu: 85Rated short-time withstand current Icw(1s): 66
ABB Air Circuit Breakers SACE Emax E1.2N 1600 Ekip Dip LI

ABB Air Circuit Breakers SACE Emax E1.2N 1600 Ekip Dip LI


SPECIFICATIONSRated uninterrupted current Iu: 1600Rated ultimate short-circuit breaking capacity Icu: 66Rated short-time withstand current Icw(1s): 50
ABB Air Circuit Breakers SACE Emax E2.2N 1000 Ekip Dip LI

ABB Air Circuit Breakers SACE Emax E2.2N 1000 Ekip Dip LI


SPECIFICATIONSRated uninterrupted current Iu: 1000Rated ultimate short-circuit breaking capacity Icu: 66Rated short-time withstand current Icw(1s): 66
ABB Air Circuit Breakers SACE Emax E1.2N 630 Ekip Dip LI

ABB Air Circuit Breakers SACE Emax E1.2N 630 Ekip Dip LI


SPECIFICATIONSRated uninterrupted current Iu: 630Rated ultimate short-circuit breaking capacity Icu: 66Rated short-time withstand current Icw(1s): 50
ABB Air Circuit Breakers SACE Emax E2.2N 1250 Ekip Dip LI

ABB Air Circuit Breakers SACE Emax E2.2N 1250 Ekip Dip LI


SPECIFICATIONSRated uninterrupted current Iu: 1250Rated ultimate short-circuit breaking capacity Icu: 66Rated short-time withstand current Icw(1s): 66