Home > Products > Circuit Breakers > CHINT Circuit Breakers

CHINT Circuit Breakers

CHINT Circuit Breakers

CHINT Vaccum Circuit Breaker ZW7-40.5 (40.5kV), Outdoor Type

CHINT Vaccum Circuit Breaker ZW7-40.5 (40.5kV), Outdoor Type


Application: in 40.5kV power system, for making and breaking load current, overload current and short circuit protection.Standards: IEC 62271-100Parameters: Rated voltage: 40.5kV. Rated current: 1250~2000A. Rated short-circuit breaking current: 20kA, 25kA, 31.5kA.Featur
CHINT Vaccum Circuit Breaker ZW8-12(Z) (12kV), Outdoor Type

CHINT Vaccum Circuit Breaker ZW8-12(Z) (12kV), Outdoor Type


Application: in 12kV power distribution system for control and protection. Standards: IEC 62271-100Parameters: Rated voltage: 12kV. Rated current: 630-1000A. Rated short-circuit breaking current: 12.5-20kA.Features: 1.Low loss for the control unit.
CHINT Vaccum Circuit Breaker ZW32-12 (12kV),Outdoor Type

CHINT Vaccum Circuit Breaker ZW32-12 (12kV),Outdoor Type


Ratings: voltage up to 10kV, current 630A, AC50Hz.Application: for making & breaking load current, overload current and short-circuit protection of electric systems and equipments. Standard: IEC62271-100
CHINT Vaccum Circuit Breaker NVW2-12Y1250-25 (12kV), Outdoor Type

CHINT Vaccum Circuit Breaker NVW2-12Y1250-25 (12kV), Outdoor Type


Application: for making and breaking load current, overload current and short-circuit current in 12kV AC50Hz power system, protecting and controlling of substation and equipments. Standards: IEC 62271-100 Parameters: Rated voltage: 12kV. Rated current: 630-1250A.
CHINT Vaccum Circuit Breaker NVW5 (12kV), Outdoor Type

CHINT Vaccum Circuit Breaker NVW5 (12kV), Outdoor Type


Application: for making and breaking load current, overload current and short-circuit current in 12kV AC50Hz power system, protecting and controlling of substation and equipments. Standards: IEC 62271-100Parameters: Rated voltage: 12kV. Rated current: 630A. Rated
CHINT Vaccum Circuit Breaker ZN85-40.5 (40.5kV), Indoor Type

CHINT Vaccum Circuit Breaker ZN85-40.5 (40.5kV), Indoor Type


Application: in 40.5kV power distribution system for control and protection. Standards: IEC 62271-100Parameters: Rated voltage: 40.5kV. Rated current: 630-2000A. Rated short-circuit breaking current: 20-31.5kA.Features: 1.High insulation level and breaking capac
CHINT Vaccum Circuit Breaker ZN63A-12(VS1) (12kV), Indoor Type

CHINT Vaccum Circuit Breaker ZN63A-12(VS1) (12kV), Indoor Type


Application: in 12kV power distribution system for control and protection. Standards: IEC 62271-100Parameters: Rated voltage: 12kV. Rated current: 630-5000A. Rated short-circuit breaking current: 20-50kA.Features: 1.Advanced arc-extinguishing mode adopted.
CHINT Vaccum Circuit Breaker NV1 Series (17.5kV,24kV), Indoor Type

CHINT Vaccum Circuit Breaker NV1 Series (17.5kV,24kV), Indoor Type


Ratings: Rated voltage 17.5kV~24kV, Rated current 630A~3150A, AC50HZApplication: for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network. Standard: IEC62271-100
CHINT Vaccum Circuit Breaker NV2 Series (12kV)

CHINT Vaccum Circuit Breaker NV2 Series (12kV)


Ratings: Rated voltage 12kV, Rated current 630A~4000A, AC50HZ Application: for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network. Standard: IEC62271-100
CHINT HV Circuit Breaker LW8-40.5 SF6

CHINT HV Circuit Breaker LW8-40.5 SF6


Application: For control and protection of 40.5kV power system.Standards: IEC 62271-100Parameters: Rated voltage: 40.5kV. Rated current: 2000A. Rated short-circuit breaking current: 31.5kA.Features: 1.With CT14 spring operation mechanism. 2.High breaking capac